Article
  • Synthesis of Melamine Phosphate-Polyurethane Composite Foam Blown by Water and Characterization of Its Thermal Properties
  • Park KK, Lee SH
  • H2O로 발포된 멜라민포스페이트-폴리우레탄폼 복합체 합성과 열적 특성 분석
  • 박경규, 이상호
Abstract
Polyurethane/melamine phosphate composite foam (MP-PUF) was prepared from poly(adipate)diol/melamine phosphate composite (f=2), polyether-polyol (f=4.6), and PMDI (f=2.5). The thermal properties of MP-PUF such as morphology, closed-cell content, thermal conductivity, and thermal stabilities were characterized. Water was used as a blowing agent, and the composition of melamine phosphate (MP) was maintained at 1.43±0.3 wt% of MP-PUF. As the content of water increased, the thermal conductivity of pure polyurethane foam (PUF) decreased, whereas the thermal conductivity of MP-PUF increased. The thermal stabilities of the PUF and the MP-PUF were maximized at 5 php H2O, and then decreased at the higher H2O contents. The thermal stabilities of MP-PUF were greatly enhanced due to the synergetic effect of MP and urea, which was generated during the blowing process. The temperature of 50% residual mass of MP-PUF increased to 370~450 ℃ and the temperature of 30% residual mass exceeded over 700 ℃. Compared to the PUF, the temperature of 50% residual mass and 30% residual mass were higher than 25 and 70 ℃, respectively.

멜라민포스페이트(MP)가 분산된 폴리우레탄폼 복합체(MP-PUF)를 만들고, MP-PUF의 모폴로지, 독립기포율, 열전도율, 열분해온도 등을 분석하였다. MP-PUF는 MP가 분산된 폴리아디페이트디올(f=2), 폴리에테르-폴리올(f=4.6)과 PMDI(f=2.5)를 원료로 사용하고 발포제로 H2O 양을 변화시키며 제조하였다. 폴리우레탄폼의 MP 함량은 1.43±0.30 wt%로 고정하였다. H2O의 양이 증가할수록 순수한 폴리우레탄폼(PUF)의 열전도율은 낮아지고 MP-PUF의 열전도율은 커졌다. PUF와 MP-PUF의 열안정성은 H2O 양이 5 php에서 최대가 되었다가 그 이상에서는 낮아졌다. 특히, MP-PUF는 발포과정에 생성된 우레아기와 MP의 영향으로 열안정성이 크게 향상되어 MP-PUF의 잔량이 50%가 되는 온도가 370~450 ℃, 잔량이 30%가 되는 온도는 700 ℃ 이상으로 PUF에 비하여 각각 25, 70 ℃ 이상 높아졌다.

Keywords: polyurethane foam; melamine phosphate; composites; themal conductivity; thermal stabilities.

References
  • 1. Kim SS, Park JN, Polym. Sci. Technol., 10(5), 614 (1999)
  •  
  • 2. Jarfelt U, Ramnas O, The 10th International Symposium on District Heating and Cooling, September 3-5, Hanover (2006)
  •  
  • 3. Lim H, Kim SH, Kim BK, J. Appl. Polym. Sci., 110(1), 49 (2008)
  •  
  • 4. Lim H, Kim SH, Kim BK, Polym. Adv. Technol., 19, 1729 (2008)
  •  
  • 5. Kim SH, Lee MC, Kim HD, Park HC, Jeong HM, Yoon KS, Kim BK, J. Appl. Polym. Sci., 117(4), 1992 (2010)
  •  
  • 6. Seo WJ, Sung YT, Kim SB, Lee YB, Choe KH, Choe SH, Sung JY, Kim WN, J. Appl. Polym. Sci., 102(4), 3764 (2006)
  •  
  • 7. Saha MC, Kabir ME, Jeelani S, Mater. Sci. Eng. A, 479, 213 (2008)
  •  
  • 8. Kim CB, Seo WJ, Kwon OD, Kim SB, Appl. Chem. Eng., 22(5), 540 (2011)
  •  
  • 9. Lorenzetti A, Modesti M, Besco S, Hrelja D, Danadi S, Polym. Degrad. Stabil., 96, 1455 (2011)
  •  
  • 10. Park KK, Lee SH, Elastom. Compos., 46, 343 (2011)
  •  
  • 11. Shufen L, Zhi J, Kaijun Y, Shuqin Y, Polym. Plast. Technol. Eng., 45, 95 (2006)
  •  
  • 12. Thirumal M, Khastgir D, Nando GB, Naik YP, Singha NK, Polym. Degrad. Stabil., 95, 1138 (2010)
  •  
  • 13. Morgan AB, Wilkie CA, Flame Retardant Polymer Nanocomposites, John Wiley & Sons Inc, New Jersey, USA (2007)
  •  
  • 14. Camino G, Costa L, Martinasso G, Polym. Degrad. Stabil., 23, 359 (1989)
  •  
  • 15. Bourbigot S, Bras ML, Delobel R, Brant P, Trmillon JM, Carbon, 33, 283 (1995)
  •  
  • 16. Jahromi S, Gabrielse W, Braam A, Polymer, 44(1), 25 (2003)
  •  
  • Polymer(Korea) 폴리머
  • Frequency : Bimonthly(odd)
    ISSN 0379-153X(Print)
    ISSN 2234-8077(Online)
    Abbr. Polym. Korea
  • 2023 Impact Factor : 0.4
  • Indexed in SCIE

This Article

  • 2014; 38(4): 441-448

    Published online Jul 25, 2014

  • Received on Dec 11, 2013
  • Accepted on Mar 20, 2014