The porous and nonporous aminated poly (styrene-co-divinylbenzene) and porous poly (4-vinylpyridine-co-divinylbenzene) resin beads of 50-100 mesh were prepared by the suspension polymerization in order to separate boron isotopes
l0B and
l1B. After 0.1M boric acid containing l0% fructose solution was passed through the column, the boric acid band formed on the column was eluted with pure water. The flow rate of breakthrough and reverse breakthrough was 10m1/hr. The contents of boric acid of the each fraction was determined with neutralization titrations. The relative mass of boron isotopes of the fractions were analyzed on a mass spectrometer
l0B was enriched at the rear part of chromatogram and
l1B was enriched at the front part of it. The separation factor of
l0B and
l1B isotopes for the P-4VPCODVB, N-ASTCODVB and P-ASTCODVB by the column chromatography were 1.0050±0.003, 1.0071±0.0003 and 1.0082±0.0003