In this study, an optimal
composition of hybrid fillers was sought to be filled in hybrid waterproofing
polymer-modified asphalt. The hybrid waterproofing polymer-modified asphalt
filled with carbon fiber (2.5%) and stearic acid-coated CaCO3
(2.5%), which was turned out the optimal filler composition, satisfied the requirements
of tensile strength, elongation and tearing strength of KS F 3211 unlike a
waterproofing polymer-modified asphalt with a basic composition without the
hybrid fillers or with 5% CaCO3 as a conventional filler.
In addition, in case of the specimen of waterproofing polymer-modified asphalt
with a basic composition, filled with 5% CaCO3 as a conventional
filler, the requirement of water pressure of water penetration resistance
(i.e., 0.3 N/mm2) was not satisfied according to KS F 4935.
However, in case of the specimen of the hybrid waterproofing polymer-modified
asphalt filled with carbon fiber (2.5%) and stearic acid-coated CaCO3
(2.5%), the requirement of water pressure of water penetration resistance was
satisfied according to KS F 4935, even though water even penetrates at the water pressure of
0.4 N/mm2
본 연구에서는 하이브리드 방수 개질아스팔트에 충전되는 충전재와
적정조성을 도출하였다. 탄소섬유(2.5%)와 스테아릭산-코팅 탄산칼슘(2.5%)의 적정조성비를 가진 하이브리드 충전재가 첨가된
하이브리드 방수 개질아스팔트의 경우에, 하이브리드 충전재가 없는 기본조성 또는 기본조성과 기존 충전재인
탄산칼슘의 5% 조성비를 가지는 방수 개질아스팔트와 다르게, KS F
3211의 인장강도, 신장률 및 인열강도의 요구조건을 만족하였다. 또한 기본조성과 방수 개질아스팔트의 기존 충전재인 탄산칼슘의 5% 조성비를 가지는 방수 개질아스팔트의
경우에는 수압이 0.3 N/mm2 경우에 투수되어서 KS F 4935의 투수저항성능 시험의 요구조건을 만족시키지 못하였으나, 적정조성비를 가진 하이브리드 방수 개질아스팔트 시편에 대한 투수저항성능 시험에서는 0.4 N/mm2의 수압에서 투수가 되었음에도 불구하고, 수압이 0.3 N/mm2 경우에 투수되지
않아서 투수저항성능에서 KS F 4935를 만족시켰다.
Keywords: hybrid waterproofing polymer-modified asphalt, carbon fiber, stearic acid-coated CaCO3, hybrid fillers
2020; 44(1): 1-5
Published online Jan 25, 2020
Department of Chemical Engineering, Daegu University, Gyeongbuk 38453, Korea